In this section, we first present experimental simulation results and | |
then validate the mathematical model presented in Section~\ref{model}. | |
\subsection{Experimental Setup} | |
In order to quantify the impact of our energy conservation methods, | |
we use various workloads that approximate usage in a cloud storage | |
system. The three workloads come from Google, the University of | |
Connecticut Hornet HPC system, and the GRID5000 platform. These workloads | |
are described in more detail below. The jobs in these workloads | |
are tied to users and each job is assumed to use the storage system equally. | |
\subsubsection{Workloads} | |
\paragraph{Google Trace} | |
The Google Trace is a log of jobs that are run in Google's cloud | |
system~\cite{clusterdata:Wilkes2011}. This trace has 29 days of data | |
collected from nearly 11,000 machines in May 2011 and it stores | |
detailed information (including storage space used) for each \textit{task}, | |
\textit{job} and \textit{machine event}. We use the data from individual tasks in the | |
evaluations as each job comprises multiple tasks. Each task has a status | |
code indicating the current status of the task - such as submission, failure, | |
re-submission, completion etc. For our test purposes, we only consider tasks | |
that are submitted and completed successfully. The Google trace is a highly | |
intensive workload, consisting of nearly 16 million tasks. We found the number | |
of users in this workload to be 100 (after unhashing the user names). | |
\paragraph{Hornet Cluster} | |
The Hornet Cluster~\cite{hornet} is a high end cluster at the University | |
of Connecticut consisting of 64 nodes where each node has 12 Intel Xeon X5650 | |
Westmere cores, 48 GB of RAM and 500 GB of storage. Information about each | |
job executed on this cluster is recorded in the log files. For each job, the log files | |
provide the identifier of the user who submitted the job, in addition to the | |
submission and completion times. The log file comprises 25 months of data | |
collected between September 2011 and October 2013. While the Hornet cluster | |
is not a cloud system, it is representative of cluster jobs that may run on | |
a cloud compute system. The Hornet cluster workload includes about 145,000 | |
jobs from 307 users. | |
\paragraph{GRID5000 Workload} | |
GRID5000 is a grid platform located in France comprising of nine separate computing | |
sites with a total of fifteen clusters available. Although a grid may not necessarily | |
be classified as a cloud platform, it has an architecture similar to a cloud system, | |
making GRID5000 a useful workload for our evaluations. GRID5000 workload~\cite{grid5000} | |
stores information about jobs submitted between May 2004 and November 2006. There is | |
no record of storage space usage in this workload. Therefore, we randomly generated | |
that for each user. GRID5000 workload consists of nearly one million jobs from 645 | |
users. | |
\subsubsection{Test Parameters} | |
We test each workload with the parameters shown in Table~\ref{tbl:params}. We assume each storage | |
node consumes 300 Watts of power~\cite{DBLP:journals/computer/BianchiniR04}. | |
\begin{table}[!htbp] | |
\begin{center} | |
\begin{tabular}{|l|l|} \hline | |
Test Parameter & Values \\ \hline | |
Total number of nodes & 64 \\ \hline | |
Number of nodes allocated & 8 \\ | |
for each user & \\ \hline | |
Allocation methods & Fixed, Dynamic Greedy, Correlation-Based \\ \hline | |
Low-energy mode & Turn Off \\ \hline | |
Inactivity threshold & 300, 1800, 3600 s \\ \hline | |
Startup time & 30, 60, 90 s \\ \hline | |
Similarity threshold & 3600, 7200, 14400 s \\ \hline | |
Storage space and on-time & 0, 0.5, 1 \\ | |
balancing weights & \\ \hline | |
Power consumption per node & 300 W \\ \hline | |
Workloads & Google, Hornet, GRID5000 \\ \hline | |
\end{tabular} | |
\end{center} | |
\caption{Test Parameters} | |
\label{tbl:params} | |
\end{table} | |
\subsection{Comparison of Energy Savings} | |
Before delving into detailed analysis of each proposed method, we first present a general comparison | |
of the proposed methods in terms of energy consumption as shown in Figure~\ref{bigresult}. This figure | |
shows the energy consumption of each workload in the Fixed scheme, Dynamic Greedy scheme, Correlation-Based | |
scheme and the stock case, where there is no energy saving mechanism in place (system always on). The total | |
number of storage nodes in the system is 64 and 8 nodes are allocated for each user. Additionally, the initial | |
technique is balancing with both storage space and on-time balancing weights ($S_W\ \ and\ \ T_W$) equal to 0.5 | |
and energy consumption weight ($E_W$) | |
equal to one. For Dynamic Greedy and Correlation-Based schemes evaluations are done every 20 days and | |
the last 24 hours are checked at every evaluation. For the Correlation-Based scheme the similarity threshold | |
is one hour. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG5.pdf} | |
\caption{Energy consumption comparison of methods} | |
\label{bigresult} | |
\end{figure} | |
Figure~\ref{bigresult} shows that, for the Google trace any of the methods would deliver the same amount | |
of energy savings and the percentage of energy savings is 8.4\% at its maximum. Google trace is a highly | |
I/O intensive workload and there are not many idle periods in the system. As a result, energy savings are | |
not significant. For Hornet cluster data and GRID5000 workload, we observe that all three workloads save | |
significant amount of energy. For both of these workloads, we see that Dynamic Greedy scheme does not | |
improve on energy consumption that much compared to the Fixed scheme. One of the main objectives of the | |
Dynamic Greedy scheme is to balance load across the storage system. As a result, balancing the load | |
across the system prevents further energy savings. Correlation-Based scheme provides slightly better energy | |
savings for GRID5000 workload and much better energy savings for Hornet cluster data. Hornet cluster is mostly | |
used by researchers working simultaneously on a project which potentially improves the correlation | |
between storage system users. For Hornet cluster data the energy savings are as high as 55\% and | |
for GRID5000 workload energy savings are as high as 50.9\%. | |
\subsection{Fixed Scheme} | |
We first evaluate the Fixed scheme, where one of the node allocation techniques (balancing, sequential, | |
random or groups) is chosen and kept active unless manually changed. We calculate the total | |
energy consumption, load balance and latency per access with 64 total nodes in the system, | |
where 8 nodes are allocated for each user. Figure~\ref{firstresult} shows how energy consumption, load balance | |
and latency per access change with each node allocation technique. \textit{Random} node allocation technique is | |
executed five times and the average result is reported, as it can yield to a different result | |
at each run. Due to space considerations, we show only the Google trace evaluations of the Fixed scheme, | |
as other workloads have similar results. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG6.pdf} | |
\caption{Allocation technique vs energy consumption, load balance and latency per access (Fixed scheme - Google trace)} | |
\label{firstresult} | |
\end{figure} | |
As seen in Figure~\ref{firstresult}, each node allocation technique saves some amount of energy | |
compared to the stock case where there is no energy saving technique in place (system always on). | |
The percentage of savings is around 8.4\% for the Google trace. Google trace is highly intensive and as a | |
result, there are not that many idle periods in this workload. Therefore, energy savings are limited in | |
such a busy workload. | |
The amount of energy savings does not | |
vary much with different techniques. Balancing technique with on-time balancing weight ($T_W$) set to | |
one consumes slightly more energy compared to other techniques. The primary objective of balancing technique | |
with on-time balancing weight set to one is to balance the on-time of nodes across the storage system. We found | |
from the Google trace that majority of the storage system accesses are in the range of couple hundred seconds. | |
Google trace workload is already balanced initially in terms of node on-time; therefore, balancing technique | |
with on-time balancing weight set to one does not change the node allocations as much as other techniques do, | |
resulting in higher energy consumption. | |
However, the techniques do differ considerably in terms of balancing storage space and on-time. Second sub-plot in | |
Figure~\ref{firstresult} shows how the coefficient of variation (CV) of storage space and on-time across the storage nodes | |
vary with different node allocation techniques. As shown in the second sub-plot of Figure~\ref{firstresult}, the | |
balancing technique with non-zero storage space balancing weight ($S_W$) has smaller CV | |
of storage space across the storage nodes. Other techniques do not perform that well as their primary objective | |
is not to balance storage space across the storage nodes. | |
The balancing technique also performs well for balancing on-time of the storage nodes, as shown in the second sub-plot | |
of Figure~\ref{firstresult}. Balancing technique with time balancing weight ($T_W$) set to one has the smallest CV | |
of on-time across the storage nodes as expected. | |
The third sub-plot in Figure~\ref{firstresult} shows how the latency per access changes with each node allocation technique. | |
As we have mentioned previously, balancing technique with on-time balancing weight set to one does not change the node | |
allocations as much as other techniques do. As a result, that technique has the smallest latency per access. On the | |
other hand, balancing technique with both storage and on-time balancing weight set to 0.5 has the highest energy savings | |
compared to other techniques; increasing its latency per access. In general, we can see that all techniques have very | |
close latency per access values, usually around 0.1 seconds. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG7.pdf} | |
\caption{The effect of varying the startup time (Fixed scheme - Google trace)} | |
\label{secondresult} | |
\end{figure} | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG8.pdf} | |
\caption{The effect of varying the inactivity threshold (Fixed scheme - Google trace)} | |
\label{thirdresult} | |
\end{figure} | |
We also investigate how the total energy consumption, load balance and latency per access is affected by the changes in | |
the startup time and inactivity threshold. Figure~\ref{secondresult} shows the total energy consumption, | |
load balance and latency per access measurements while the startup time is varied between 30, 60 and 90 seconds. Similarly, | |
Figure~\ref{thirdresult} shows the total energy consumption, load balance and latency per access measurements while the | |
inactivity threshold is varied between 300, 1800 and 3600 seconds. As each technique is affected similarly by the changes | |
in the inactivity threshold and startup time, we only present results for the balancing technique with both storage space | |
and on-time balancing weights ($S_W$ and $T_W$) equal to 0.5 and energy consumption weight ($E_W$) equal to zero. | |
As we can see in both Figure~\ref{secondresult} and Figure~\ref{thirdresult}, changing the inactivity threshold or the | |
startup time has nearly no effect on the load balance. Changing the startup time does not affect the energy consumption | |
either. Figure~\ref{thirdresult} shows that increasing the inactivity threshold causes energy consumption to go up. When | |
the inactivity threshold is higher, it is less likely for a storage node to be turned-off for being idle longer | |
than this threshold. This causes the storage node to stay on for longer and consequently increases energy consumption. | |
Latency per access slightly increases as the startup time is increased. This is expected, since any access that is made | |
to a turned-off node will wait longer for that node to startup again. On the other hand, as the inactivity threshold is | |
increased, latency per access slightly decreases. In that case, the storage nodes are kept on for longer due to higher | |
inactivity threshold; which means that less storage system accesses will be made to a turned-off node. | |
\subsection{Dynamic Greedy Scheme} | |
In this section, we evaluate the Dynamic Greedy scheme and find out how effective it is in terms of energy consumption, | |
load balance and latency per access. As discussed in Section~\ref{greedy}, \textit{evaluation points} and | |
\textit{control periods} are two important parameters of the Dynamic Greedy scheme. Dynamic Greedy scheme starts with | |
one of the four node allocation techniques we proposed (balancing, sequential, random or grouping) and changes between | |
these techniques at evaluation points, if necessary. We try to understand if the initial technique chosen has any effect | |
on the energy consumption, load balance or latency. We also analyze the effect of varying evaluation points and | |
control periods on the energy consumption, load balance and latency per access. | |
To start with, we test the Dynamic Greedy scheme with varying storage-space, on-time and energy consumption weights | |
($S_W$, $T_W$ and $E_W$) where the total number of storage nodes in the system is 64 and the number of nodes allocated | |
for each user is 8, as shown in Figure~\ref{fourthresult}. The evaluations are done every 2 days and the storage | |
accesses in the last 6 hours are checked. Each measurement is the average of five runs. Due to space considerations, we | |
show only the Hornet cluster evaluations of the Dynamic Greedy scheme, as other workloads have similar results. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG9.pdf} | |
\caption{Initial technique vs energy consumption, load balance and latency per access (Dynamic Greedy scheme - Hornet cluster)} | |
\label{fourthresult} | |
\end{figure} | |
Figure~\ref{fourthresult} shows that the Dynamic Greedy scheme saves a considerable amount of energy regardless of | |
which node allocation technique is chosen initially. The percentage of energy savings are between 43.4\% and 52\% | |
for varying storage space, on-time and energy weights. Regardless of which technique is initially chosen, we can | |
see that cases where the energy consumption weight ($E_W$) is set to one consume less energy compared to the cases | |
where the energy consumption weight is set to zero. Another observation we can make is that the cases where the | |
on-time balancing weight ($T_W$) is non-zero and energy consumption weight ($E_W$) is set to zero consume more | |
energy. In the Hornet cluster workload, storage system access lengths vary significantly. As a result, | |
while trying to balance the on-time across the storage nodes, it is more likely to transfer users from one node | |
to another. Storage space usage among the users vary as well, though not as much as the access lengths. | |
In the second sub-plot of Figure~\ref{fourthresult}, we can see how the CVs of storage space and | |
on-time change when the storage space, on-time and energy consumption weights are varied. Regardless of | |
which allocation technique is chosen initially (balancing, sequential, random or grouping) the CVs of the | |
storage space and on-time are similar. Therefore, we only show the results for cases where balancing technique | |
is the initially chosen technique. We can see that the CV of the storage space is the smallest when the storage space | |
balancing weight ($S_W$) is set to one, regardless of the energy consumption weight ($E_W$). As the on-time | |
balancing weight ($T_W$) is increased, the CV of the storage space increases as well. The same holds true | |
for the CV of the on-time. When the on-time balancing weight ($T_W$) is set to one, the CV of the on-time | |
is the smallest regardless of the energy consumption weight ($E_W$). As the storage space balancing | |
weight ($S_W$) is increased, the CV of the on-time increases as well. | |
We can see how latency per storage access changes with varying storage space, on-time and energy consumption | |
weights in the third sub-plot of Figure~\ref{fourthresult}. Again, as it does not matter which allocation technique | |
is initially chosen, we only show the results for cases where the balancing technique is the initially chosen | |
technique. The latency | |
measurements are almost the inverse of the energy consumption measurements in the first sub-plot of | |
Figure~\ref{fourthresult}. In the first sub-plot of Figure~\ref{fourthresult}, we have seen that when the energy | |
consumption weight ($E_W$) is set to one, the energy consumption goes down. This means that a storage access | |
will most likely be made on a turned-off node, increasing latency per access. We have also seen in the | |
first sub-plot of Figure~\ref{fourthresult} that when on-time balancing weight is non-zero and the energy | |
consumption weight ($E_W$) is set to zero, the energy savings are less. This will in turn | |
decrease the chance of an access to be made to a turned-off node, decreasing latency per access. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG10.pdf} | |
\caption{The effect of varying the evaluation frequency (Dynamic Greedy scheme - Hornet cluster)} | |
\label{fifthresult} | |
\end{figure} | |
We now look at the effect of varying the evaluation frequency on the total energy consumption, | |
load balance and latency per access. The evaluation frequency is varied between 2, 10 and 20 days | |
and the control period is fixed at 6 hours. Since the initial allocation technique does not change | |
the results, we initially start with the balancing technique with both storage space and on-time | |
balancing weights ($S_W$ and $T_W$) set to 0.5 and energy consumption weight ($E_W$) set to zero. | |
As shown in Figure~\ref{fifthresult}, total energy consumption goes down as the evaluation frequency | |
becomes longer. When the evaluation frequency is longer, our algorithms have more knowledge about | |
the state of the storage system. Therefore, more intelligent decisions are made for reducing energy | |
consumption. We also see that the CVs of the storage space and on-time is almost not affected by | |
the evaluation frequency. In the third sub-plot of Figure~\ref{fifthresult}, we observe that latency | |
per access increases as the evaluation frequency becomes longer. This is expected, as longer evaluation | |
frequency reduces energy consumption by turning off storage nodes more often. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG11.pdf} | |
\caption{The effect of varying the control period (Dynamic Greedy scheme - Hornet cluster)} | |
\label{sixthresult} | |
\end{figure} | |
Figure~\ref{sixthresult} shows the effect of varying the control period (between 6, 12 and 24 hours) | |
on the total energy consumption, load balance and latency per access. In this test case the evaluation | |
frequency is fixed at 2 days. The results in Figure~\ref{sixthresult} indicate that varying the control | |
period does not affect the total energy consumption, load balance or latency per access. | |
\subsection{Correlation-Based Scheme} | |
In this section, we evaluate the Correlation-Based scheme and find out how effective it is in terms of energy consumption, | |
load balance and latency per access. Correlation-Based scheme starts with one of the four node allocation | |
techniques (balancing, sequential, random or grouping) similar to the Dynamic Greedy scheme. Unlike the Dynamic | |
Greedy scheme, it checks the correlations between users at evaluation points and allocates the same storage | |
nodes for correlated users instead of changing the initial node allocation technique. As a matter of fact, | |
initial node allocation technique is used if only a user accesses the storage system for the first time. | |
During the following tests, we also try to understand if the initial technique chosen has any effect on the | |
energy consumption, load balance or latency per access. | |
Correlation-Based scheme also has \textit{evaluation point} and \textit{control period} parameters. We have | |
already shown the effect of varying these two parameters for the Dynamic Greedy scheme; therefore, we are not | |
repeating the same tests for Correlation-Based scheme. \textit{Similarity threshold} is a parameter that | |
is unique to the Correlation-Based scheme. We look at the effect of this parameter on the energy consumption, | |
load balance and latency per access as well. | |
To start with, we test the Correlation-Based scheme with different initial techniques, where the total number of | |
storage nodes in the system is 64 and the number of nodes allocated for each user is 8, as shown in | |
Figure~\ref{seventhresult}. The evaluations are done every 2 days and the storage accesses in the last 6 hours | |
are checked. Each measurement is the average of five runs. Since energy consumption weight is not important | |
in Correlation-Based scheme, it is fixed at zero in this test case. Due to space considerations, we | |
show only the GRID5000 workload evaluations of the Correlation-Based scheme, as other workloads have similar | |
results. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG12.pdf} | |
\caption{Initial technique vs energy consumption, load balance and latency (Correlation-Based scheme - | |
GRID5000 workload)} | |
\label{seventhresult} | |
\end{figure} | |
Figure~\ref{seventhresult} shows that Correlation-Based Scheme saves more than half of the energy consumed | |
in the stock case regardless of the initial node allocation technique. The percentage of energy savings | |
are as high as 60\%. We observe that the initial technique chosen does not have a significant effect on | |
the energy consumption. | |
The CVs of the storage space and on-time are shown in the second sub-plot of Figure~\ref{seventhresult}. | |
As the initial technique chosen for the Correlation-Based scheme does not really matter, we show | |
results for the balancing technique with varying storage-space and on-time balancing weights. As the | |
storage space balancing weight ($S_W$) is increased, the CV of the storage space | |
decreases. The same is true for on-time. | |
The third sub-plot in Figure~\ref{seventhresult} shows how latency per access is affected when the initial | |
technique is balancing with varying storage-space and on-time balancing weights. In GRID5000 workload, the | |
storage space usage of users are close to each other. Therefore balancing technique with storage-space | |
balancing weight set to one will not effect the node allocations as much as other techniques do. We observed | |
that GRID5000 workload havs accesses of varying lengths, particularly | |
until the first evaluation point. As a result, if both the storage space balancing and on-time weight are set | |
to 0.5, then the algorithm will not try to break already balanced storage-space distribution, while at the | |
same time trying to balance on-time. This will in turn result in more transfers and consequently more latency. | |
This feature of the GRID5000 workload is similar to that of Google trace in Figure~\ref{firstresult}, except | |
that Google trace had varying storage space usage among the users where access lenghts did not vary that much. | |
\begin{figure}[!htbp] | |
\centering | |
\includegraphics[width=\columnwidth,keepaspectratio]{FIG13.pdf} | |
\caption{The effect of varying the similarity threshold (Correlation-Based scheme - GRID5000 workload)} | |
\label{eightthresult} | |
\end{figure} | |
Figure~\ref{eightthresult} shows the effect of varying the similarity threshold on the total energy | |
consumption, load balancing and latency per access. Evaluations are done every 2 days and the last 6 hours | |
are checked at every evaluation. Balancing technique with both storage space and on-time balancing | |
weights set to 0.5 is used initially. Similar to the inactivity threshold, varying the | |
similarity threshold has almost no effect on the standard devations of the storage space and on-time | |
or latency per access. When the similarity threshold is increased, total energy consumption | |
increases slightly. The higher the similarity threshold is, the less likely it is to find correlated | |
users. As a result, energy consumption goes up with higher similarity threshold. | |
\subsection{Validating Mathematical Model} | |
\label{validate_model} | |
We have validated the mathematical model presented in Section~\ref{model} against the | |
experimental results of our approach using data from Hornet HPC system. We can estimate the energy | |
consumption, load balancing and latency per access values for each workload | |
by using the mathematical model presented in Section~\ref{model}. We validate | |
the mathematical model using the subset of test parameters as shown in | |
Table~\ref{tbl:validate_params}. | |
For brevity, we show only the Hornet data, though the other workloads show similar results. | |
For the Hornet data that we show here for this validation, we have primarily used a Generalized | |
Extreme Value interjob arrival model - i.e. | |
$F(t) = e^{-g(t)},\ \ where\ \ g(t)\ \ =\ \ [{1 + (\frac{t - \mu}{\sigma}) * \xi}]^{\frac{-1}{\xi}}$ | |
and $\xi,\ \ \mu$ and $\sigma$ are distribution parameters. | |
\begin{table}[!htbp] | |
\begin{center} | |
\begin{tabular}{|l|l|} \hline | |
Test Parameter & Values \\ \hline | |
Total number of nodes & 64 \\ \hline | |
Number of nodes allocated & 8 \\ | |
for each user & \\ \hline | |
Allocation methods & Fixed, Dynamic Greedy, Correlation-Based \\ \hline | |
Low-energy mode & Turn Off \\ \hline | |
Inactivity threshold & 300 s \\ \hline | |
Startup time & 30 s \\ \hline | |
Similarity threshold & 3600 s \\ \hline | |
Storage space and on-time & 0.5, 0.5, 0 \\ | |
balancing weights & \\ \hline | |
Power consumption per node & 300 W \\ \hline | |
Workloads & Hornet \\ \hline | |
\end{tabular} | |
\end{center} | |
\caption{Mathematical Model Validation Parameters} | |
\label{tbl:validate_params} | |
\end{table} | |
Tables~\ref{tbl:validate_results_fixed},~\ref{tbl:validate_results_dynamic} and ~\ref{tbl:validate_results_corr} show | |
that the mathematical model we presented is able to estimate the test result parameters (CV of storage space, CV of on-time | |
, energy cost and latency per access) accurately in most | |
cases. The storage space usage of a user per storage node does not change over time; therefore, the chance of | |
estimating it accurately is high. Our model estimates on-time value and energy consumption of each storage node accurately | |
as well, as estimating them involves all of the parameters captured by our model except storage space usage. | |
Latency per access is highly dependent on the arrival rate of \textit{interarrivals} and our model does the best attempt to | |
capture these interarrivals in order to estimate the latency per access. | |
\begin{table}[!htbp] | |
\begin{center} | |
\resizebox{\textwidth}{!}{% | |
\begin{tabular}{lcccccccc} \hline | |
\multicolumn{1}{|c}{} & \multicolumn{4}{c|}{Balancing} & \multicolumn{4}{c|}{Sequential}\\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} & \multicolumn{1}{c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} \\ | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} \\ \hline | |
\multicolumn{1}{|l|}{Simulation} & 0.539 & 0.312 & 195.65 & \multicolumn{1}{c|}{1.0348} & 0.757 & 0.382 & 181.01 & \multicolumn{1}{c|}{1.1833} \\ | |
\multicolumn{1}{|l|}{Model} & 0.543 & 0.3145 & 195.62 & \multicolumn{1}{c|}{1.1657} & 0.7628 & 0.3849 & 180.93 & \multicolumn{1}{c|}{1.1669} \\ | |
\multicolumn{1}{|l|}{Error} & 0.74\% & 0.80\% & 0.02\% & \multicolumn{1}{c|}{12.65\%} & 0.77\% & 0.76\% & 0.04\% & \multicolumn{1}{c|}{1.39\%} \\ \hline | |
& & & & & & & & \\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{4}{c|}{Random} & \multicolumn{4}{c|}{Groups}\\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} & \multicolumn{1}{c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} \\ | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} \\ \hline | |
\multicolumn{1}{|l|}{Simulation} & 0.9 & 0.394 & 179.81 & \multicolumn{1}{c|}{1.5673} & 1.129 & 0.351 & 183.78 & \multicolumn{1}{c|}{1.0367} \\ | |
\multicolumn{1}{|l|}{Model} & 0.9069 & 0.3973 & 179.753 & \multicolumn{1}{c|}{1.2496} & 1.1381 & 0.3539 & 183.711 & \multicolumn{1}{c|}{1.0539} \\ | |
\multicolumn{1}{|l|}{Error} & 0.77\% & 0.84\% & 0.03\% & \multicolumn{1}{c|}{20.27\%} & 0.81\% & 0.83\% & 0.04\% & \multicolumn{1}{c|}{1.66\%} \\ \hline | |
\end{tabular}} | |
\end{center} | |
\caption{Mathematical Model Validation Results for Fixed Scheme} | |
\label{tbl:validate_results_fixed} | |
\end{table} | |
\begin{table}[!htbp] | |
\begin{center} | |
\resizebox{\textwidth}{!}{% | |
\begin{tabular}{lcccccccc} \hline | |
\multicolumn{1}{|c}{} & \multicolumn{4}{c|}{Starts with Balancing} & \multicolumn{4}{c|}{Starts with Sequential}\\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} & \multicolumn{1}{c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} \\ | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} \\ \hline | |
\multicolumn{1}{|l|}{Simulation} & 0.605 & 0.0932 & 199.36 & \multicolumn{1}{c|}{1.11008} & 0.6186 & 0.0956 & 199.273 & \multicolumn{1}{c|}{1.12687} \\ | |
\multicolumn{1}{|l|}{Model} & 0.6031 & 0.1006 & 199.913 & \multicolumn{1}{c|}{1.0424} & 0.6142 & 0.1 & 200.254 & \multicolumn{1}{c|}{0.9944} \\ | |
\multicolumn{1}{|l|}{Error} & 0.31\% & 7.94\% & 0.28\% & \multicolumn{1}{c|}{6.1\%} & 0.71\% & 4.6\% & 0.49\% & \multicolumn{1}{c|}{11.76\%} \\ \hline | |
& & & & & & & & \\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{4}{c|}{Starts with Random} & \multicolumn{4}{c|}{Starts with Groups}\\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} & \multicolumn{1}{c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} \\ | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} \\ \hline | |
\multicolumn{1}{|l|}{Simulation} & 0.614 & 0.0926 & 200.199 & \multicolumn{1}{c|}{1.14529} & 0.63 & 0.086 & 200.558 & \multicolumn{1}{c|}{1.09082} \\ | |
\multicolumn{1}{|l|}{Model} & 0.6092 & 0.0923 & 199.577 & \multicolumn{1}{c|}{1.022} & 0.6382 & 0.08 & 201.176 & \multicolumn{1}{c|}{1.0311} \\ | |
\multicolumn{1}{|l|}{Error} & 0.78\% & 0.32\% & 0.31\% & \multicolumn{1}{c|}{10.76\%} & 1.3\% & 6.98\% & 0.31\% & \multicolumn{1}{c|}{5.47\%} \\ \hline | |
\end{tabular}} | |
\end{center} | |
\caption{Mathematical Model Validation Results for Dynamic Greedy Scheme} | |
\label{tbl:validate_results_dynamic} | |
\end{table} | |
\begin{table}[!htbp] | |
\begin{center} | |
\resizebox{\textwidth}{!}{% | |
\begin{tabular}{lcccccccc} \hline | |
\multicolumn{1}{|c}{} & \multicolumn{4}{c|}{Starts with Balancing} & \multicolumn{4}{c|}{Starts with Sequential}\\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} & \multicolumn{1}{c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} \\ | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} \\ \hline | |
\multicolumn{1}{|l|}{Simulation} & 2.059 & 0.35 & 120.842 & \multicolumn{1}{c|}{1.27998} & 2.108 & 0.671 & 105.857 & \multicolumn{1}{c|}{1.27017} \\ | |
\multicolumn{1}{|l|}{Model} & 2.0755 & 0.3523 & 120.798 & \multicolumn{1}{c|}{1.5492} & 2.1244 & 0.676 & 105.826 & \multicolumn{1}{c|}{1.2532} \\ | |
\multicolumn{1}{|l|}{Error} & 0.80\% & 0.66\% & 0.04\% & \multicolumn{1}{c|}{21.03\%} & 0.78\% & 0.75\% & 0.03\% & \multicolumn{1}{c|}{1.34\%} \\ \hline | |
& & & & & & & & \\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{4}{c|}{Starts with Random} & \multicolumn{4}{c|}{Starts with Groups}\\ \hline | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} & \multicolumn{1}{c}{Storage} & \multicolumn{1}{c}{On-time} & \multicolumn{1}{c}{Energy} & \multicolumn{1}{c|}{Latency per} \\ | |
\multicolumn{1}{|c}{} & \multicolumn{1}{|c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{CV} & \multicolumn{1}{c}{cost (MWh)} & \multicolumn{1}{c|}{access (s)} \\ \hline | |
\multicolumn{1}{|l|}{Simulation} & 2.056 & 0.638 & 103.395 & \multicolumn{1}{c|}{1.36857} & 2.052 & 0.835 & 107.887 & \multicolumn{1}{c|}{1.30135} \\ | |
\multicolumn{1}{|l|}{Model} & 2.072 & 0.6427 & 103.381 & \multicolumn{1}{c|}{1.5413} & 2.0678 & 0.842 & 107.851 & \multicolumn{1}{c|}{1.249} \\ | |
\multicolumn{1}{|l|}{Error} & 0.78\% & 0.74\% & 0.01\% & \multicolumn{1}{c|}{12.62\%} & 0.77\% & 0.84\% & 0.03\% & \multicolumn{1}{c|}{4.02\%} \\ \hline | |
\end{tabular}} | |
\end{center} | |
\caption{Mathematical Model Validation Results for Correlation-Based Scheme} | |
\label{tbl:validate_results_corr} | |
\end{table} |